Find Earthing Transformer, Grounding Transformer, Grounding Neutral Transformator on Industry Directory, Reliable Manufacturer/Supplier/Factory from China.
Home > Products > Grounding Transformer > Ngr High Quality Neutral Grounding Resistor
The Latest Product Alerts Send Me
Ngr High Quality Neutral Grounding Resistor
  • Ngr High Quality Neutral Grounding Resistor
  • Ngr High Quality Neutral Grounding Resistor
  • Ngr High Quality Neutral Grounding Resistor
  • Ngr High Quality Neutral Grounding Resistor
  • Ngr High Quality Neutral Grounding Resistor
  • Ngr High Quality Neutral Grounding Resistor
Payment Type: L/C, T/T, D/P
Min. Order: 1
Basic Info

Model No.:  fl

Product Description Model NO.: fl Function for Resistance: Protective Resistor Material: Wire-wound Resistor Brand: Farady Business Type: Manufacturer Specification: 1200L x 1200W x 1900H(mm) HS Code: 8537109090 Resistance: Fixed Resistor Installation: DIP Resistor Shape: Laminated Type Item: Ngr High Quality Neutral Grounding Resistor Trademark: FARADY Origin: Zhejiang, China General Farady has own R & D team with outstanding technology and sophisticated equipment, advanced technology introduction and digestion of foreign countries, long-term commitment to the production of neutral grounding technology product research and development; to reduce the overvoltage and improve the safety and reliability of the network. Farady import special stainless steel alloy materials, development and production of a series of neutral grounding resistors of the stainless steel cabinet, for 6 ~ 35kV AC network. In the system of cable power supply, the grounding capacitance current is larger. When the current is greater than the specified value will be generated when the arc grounding overvoltage. Injection of resistive current of the neutral grounding resistors mode is to give the point of failure, the fault current is resistive and capacitive properties, reduce the phase difference and voltage, reduce the fault current zero arc after the resignation rate, the overvoltage is limited within 2.6 times the phase voltage, improve the sensitivity function the relay protection on the trip, in order to effectively protect the normal operation of the system. In the 6 ~ 35kV alternating current network, especially in the network with the cable power supply, the resistance grounding is widely used. However, if the transformer winding is delta connection, neutral point grounding grid, Earthing Transformer must be installed, and a resistor is arranged between the earthing transformer neutral point and the ground. FL-NGR transformer neutral grounding resistor cabinet is a farady with complete sets of equipment including earthing transformer, the development requirements of these systems can be installed in the power plant power system, substation power supply system, industrial and mining enterprises in the distribution system, the realization of these grid uses in point via neutral grounding resistor system.   Service condition 1, Altitude: no more than 4000m 2, ambient temperature: -40 to +60 degrees 3, relative humidity: no more than 95% (25 degrees C) 4, the installation place: air does not contain chemical corrosion of gas and steam, no explosive dust 5, power grid frequency: 48 ~ 52Hz (50 Hz system), 58 ~ 62 Hz (60 Hz system) 6, applicable to: Indoor & Outdoor 7, resistance installation point: the normal state of the neutral point displacement does not exceed 3% of the running phase voltage   Note: special conditions of use, please enquiry Farady tech dept during ordering     Standard model and parameter

Model

System rating voltage(kV)

Short time flow current(A)

Short time flow time(S)

Rating resistance

(Ω)

FL-NGR-6/36.4

6.3

100

10

36.4

FL-NGR-6/18.2

6.3

200

10

18.2

FL-NGR-6/9.09

6.3

400

10

9.09

FL-NGR-6/6.06

6.3

600

10

6.06

FL-NGR-10/15.16

10.5

400

10

15.16

FL-NGR-10/10.10

10.5

600

10

10.10

FL-NGR-10/7.57

10.5

800

10

7.57

FL-NGR-10/6.06

10.5

1000

10

6.06

FL-NGR-35/20.20

35

1000

10

20.20

FL-NGR-35/10.10

35

2000

10

10.10

  P.S. We can design and manufacture all kinds of resistance according to user requirements, the resistance value from 1 ohm -2000, allowing the error of the current 1A-2000A. resistance value of + 3%. allows flow time 10s, 15s, 30s, 60s.

Overall size and installation
1, equipment installation wiring diagram as shown below
Ngr High Quality Neutral Grounding Resistor

2, the resistance cabinet can be fixed on the concrete foundation, to maintain the resistance level. The equipment case should be grounded by the foot of the cabinet. The external dimension of the resistance cabinet is determined according to the specific parameters of the user. The following is the outline size of FL-NGR-6/400:
Ngr High Quality Neutral Grounding Resistor
 

Contact us if you need more details on Neutral Grounding Resistor. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Neutral Earthing Resistor、Ngr. If these products fail to match your need, please contact us and we would like to provide relevant information.

Product Categories : Grounding Transformer