Model No.: TYCPT1000
Low-voltage 1000RPM Frequency Conversion three-phase PMSM
For a pumping system, the overall efficiency of the system is the product of efficiency of each energy component along the way. Optimizing one or the other of the individual components may improve overall efficiency. In this system, not only can the system save energy by choosing the appropriate pump size and operating the pump at its best efficiency point (BEP), but also by choosing the efficient energy-saving motor matching the pump (such as horizontal centrifugal slurry pump, vertical centrifugal slurry pump, water pump, mining duty pump, mineral processing pump, flotation machine feeding pump, dredge slurry pump, etc.).High efficient permanent magnet motor is a good choice. Compared with the conventional asynchronous motor, this Low-voltage 1000RPM Frequency Conversion three-phase PMSM has higher efficiency and power factor at low load rate. It should be emphasized that the application of high power factor permanent-magnet AC motor can improve the active output of the grid system and significantly reduce the operating costs of the enterprise.
Product features:
1. High Efficiency
Compared with three-phase asynchronous motor, rated efficiency is increased by more than 3%-5%, and the efficiency of low load is improved more significantly.
2. High Power Factor
The power factor is over 0.96, and even shows capacitance without reactive compensation.
3. Energy Saving and High Return
Depending on the load, the system can save about 4% - 30% energy instead of asynchronous motor.
4. Small Current
Compared with three-phase asynchronous motors, the current is reduced by more than 10% without reactive compensation. When new projects are built, the investment of cables and transformers can be greatly reduced.
5.Low Temperature Rise
Compared with the three-phase asynchronous motor, the temperature rise is reduced by 20K. When the design temperature rise is the same, it can be made into smaller volume and larger power.
6. High Starting Torque, High Overload Capacity
High starting torque (3-5 times) and high overload capacity can be designed as required.
7.Excellent Control Performance.
Permanent magnet motor control is convenient, strict synchronization, good dynamic response performance, suitable for frequency conversion control.
8. Asynchronous Motor can be Replaced Directly.
Installation dimension conforms to IEC standard and can directly replace three-phase asynchronous motor.
Motor experimental data - efficiency, power factor curve
From the test results of the motor, the permanent magnet synchronous motor has higher efficiency and power factor than the ordinary asynchronous motor under light load and rated state.
Performance List
Type | Power | Rated Current | Rated | EFF. | Power | Rated | Max | |
kW | A | Speed | Factor | Torque | Torque | |||
380V | 660V | r/min | % | cosφ | N.m | Multiple | ||
TYCPT280S-6 | 45 | 75 | 43.2 | 1000 | 94.9 | 0.96 | 429.8 | 2 |
TYCPT280M-6 | 55 | 91.4 | 52.6 | 1000 | 95.2 | 0.96 | 525.3 | 2 |
TYCPT315S-6 | 75 | 124.4 | 71.6 | 1000 | 95.4 | 0.96 | 716.3 | 1.8 |
TYCPT315M-6 | 90 | 149 | 85.8 | 1000 | 95.6 | 0.96 | 859.5 | 1.8 |
TYCPT315L1-6 | 110 | 182.1 | 104.8 | 1000 | 95.6 | 0.96 | 1050.5 | 1.8 |
TYCPT315 L2-6 | 132 | 218.1 | 125.6 | 1000 | 95.8 | 0.96 | 1260.6 | 1.8 |
TYCPT355S1-6 | 160 | 263.8 | 151.9 | 1000 | 96 | 0.96 | 1528 | 1.6 |
TYCPT355S2-6 | 185 | 304.7 | 175.4 | 1000 | 96.1 | 0.96 | 1766.8 | 1.6 |
TYCPT355M-6 | 200 | 329.4 | 189.6 | 1000 | 96.1 | 0.96 | 1910 | 1.6 |
TYCPT355L1-6 | 220 | 362.3 | 208.6 | 1000 | 96.1 | 0.96 | 2101 | 1.6 |
TYCPT355L2-6 | 250 | 411.7 | 237.1 | 1000 | 96.1 | 0.96 | 2387.5 | 1.6 |