Product Description
Model NO.: 35kv Scb11 Resin Dry Type Transformers Phase: Three Cooling Method:
Dry-Type Transformer Certification: ISO9001-2000, ISO9001, CCC Frequency Characteristics: 50-60Hz Brand: Keyuan Secondary Voltage: 10/0.4 Color: Red and blue Tap Range: ±5 or ±2X2.5% Frequency: 50Hz ,60Hz Place of Origin: Guangdong, China (Mainland) Specification: 30KVA-2500KVA HS Code: 8504 Application: Power, Electronic Coil: Core-type Transformer Winding Type: Two-winding Transformer Usage:
Power Transformer Shape of Coil: Ring product Name:
High Voltage and Big Capacity Power Transformer Rated Capacity: 30kVA-2500kVA Optional Accessories: Temperature Control, Fans, Enclosures, CT Vector Group: Dyn11 or Yyn0 Primary Voltage: 6kv/ 6.3kv/ 10kv/ 10.5kv/ 11kv/ 13.2 Kv Trademark: KEYUAN Origin: China High Voltage and Big Capacity Power Transformer
Introduction Summary
dry type transformer is in accordance with "GB 6450-86 "
Dry-type power Transformer", GB 10228-1997 "Technical Parameter and Requirement of Dry-type Power Transformer and "GB 1094.1-1996 "Power Transformer Section 1 General", and it is the Grade F or H insulation dry-type power transformer cast and molded by epoxy resin.
1. Brief Description:
The resin-insulated dry-type transformer is a safe, fire-retardant, fireproof, pollution-free transformer directly installed in load center. With the improvement of people's living condition, the urban and rural electrical load increases continuously, and the oil-free, fireproof, safe, and reliable dry-type transformer with a long service life and simple maintenance has been applied more widely.
2. Application Scope
This transformer mainly applies to hotels, high-rise buildings, business centers, residential quarters, stadiums, factories, airports, ports, subways and mines underground, etc, and is especially suitable for the areas with special fireproof requirements, for example, limited installation space and load center of cities and towns.
3. Model Description
4. Standards GB1094.1, GB1094.2, GB1094.3, GB1094.5, GB1094.11
IEC 60076-1:2000,IEC 60076-2:1993, IEC 60076-3:2000, IEC 60076-5:2006, IEC 60076-11
GB/T 10228, GB20052, etc
5. Normal Service Conditions
Height above sea level: Not greater than 1,000m;
Ambient temperature: Maximum temperature: +40ºC;
Maximum daily average temperature: +30ºC;
Maximum annual average temperature: +20ºC;
Minimum outdoor temperature: -25ºC;
Installation environment: ground acceleration caused by earthquake: ag
Contact us if you need more details on
10KV Transformer. We are ready to answer your questions on packaging, logistics, certification or any other aspects about
Dry Transformer、2000kVA Transformer. If these products fail to match your need, please contact us and we would like to provide relevant information.
Product Categories : Dry-Type Transformer